Level B Engineer (Electrical) in Birmingham, United Kingdom
Birmingham, United Kingdom |
Salary not specified |
Contract
All volunteers need to hold EFA and MH.
There are TWO identical work scopes, both based in Birmingham, as described below:
TSC Works
- Install MS146 Type 3 Enclosure at a location in close proximity to existing RTU cabinet
- Install Krone 250 junction box and termination strip for 10-pair connection on or near the existing Telecoms wallboard or panel.
- Install 50V DC supply fuse terminals in RTU at terminal block TBF-5 (Stechford TSC only)
- Install and terminate DEF STAN 61.12 screened I/O cable, minimum 6-core 0.5mm2, between MS146 Type 3 Enclosure and the RTU (EMC gland required at RTU end)
- Install and terminate screened 50V DC power supply cable, 2-core 2. 5mm2 between MS146 Type 3 Enclosure and the RTU TBF-5 (EMC gland required at RTU end)
Install and terminate twisted pair Telecoms cable between MS146 Type 3 Enclosure and the new Krone junction box / termination strip
- Level B cover to be provided by ICS for the duration of the above works, plus 0.5 days to support pre-commissioning of installed equipment.
PSP Works (precise PSP location TBC, but for the purposes of this quotation, please assume it is in a physically separate compound, no more than a 15 minute drive from the TSC)
- Strip out MS146 Type 1 Enclosure pre-wired cables I/O cable (this could be done at your premises, if preferred)
- Install MS146 Type 1 Enclosure inside PSP marshalling cabinet
- Install and terminate minimum 5-core 1. 5mm2 I/O cable between The MS146 Type 1 Enclosure input terminals and the PSP marshalling terminals
- Terminate pre-wired 240V AC power cable from the MS146 Type 1 Enclosure to the provided AC distribution point (supplied and installed by others)
- Terminate pre-wired 2-pair telecoms cable from the MS146 Type 1 Enclosure to the provided telecoms connection terminals (supplied and installed by others)
Materials
All Materials including cables, EMC/stuffing glands, Krone junction box, crimps and electrical sundries to be supplied by ICS, except:
- The MS146 master (type 3 enclosure) and slave (type 1 enclosure) will be free-issued by Siemens
- The 10-way Krone termination strip (for installation inside the Krone 250 junction box in the TSC) will be free-issued by Siemens
- Cable IDs, wire IDs and Terminal header labels will be free-issued by Siemens
- Installation to be in accordance with approved client design drawings.